Categories

To effectively select a pressure gauge, you need to consider the following:

Gauge range

The normal operating pressure should be confined to between 25% and 75% of the scale, if process pulsation is present then the maximum operating gauge pressure should not exceed 50% of the full-scale range. The scale on Brannan’s standard industrial range is usually printed in either bar, psi or dual scale (bar & psi).

 

Gauge accuracy

Accuracy is usually defined as a percentage of the full-scale range, as a guide the following is often used.

Test Gauges 0.25 to 0.1%
Critical Processes 0.5%
General Industrial Processes 1% or 2% for less critical

 

Gauge dial size

Typically, they range from 38mm (1 ½”) to 400mm (16”), with the most common being 100mm(4”) and 150mm (6”) for process gauges and 250mm (10”) for test gauges. When determining the dial size consider readability, space limitations and the gauge accuracy. Brannan’s standard industrial range covers from 38mm (1 ½”) to 150mm (6)

 

Gauge connection

Gauges are available with a variety of thread connections including BSP, NPT, DIN, JIS &SAE. The most commonly used sizes are 3/8” and ½”, Brannan’s standard industrial range covers from 1/8” to ½” in both the BSP & NPT thread form.

 

Gauge mounting

The following mounting options should be considered when selecting a pressure gauge. Brannan’s standard industrial range includes bottom, mid back & lower back connections:

 

Mounting Position Connection Position
Direct stem mount Bottom connection
Wall or surface mount Bottom connection
Panel surface mount Back connection (mid or lower)
Panel hole U-Clamp flush mount Back connection (mid or lower)
Panel hole front flange flush mount Back connection (mid or lower)

 

Gauge material

Cases are typically available in ABS plastic, painted steel, chrome plated steel, brass, stainless steel, aluminium and phenolic turret. Cases are available in three types with Type 3(solid front case) offering the highest level of protection should a gauge fail. The material selection and safety requirement should be based on the environment in which the gauge is to operate. The cases in Brannan’s standard industrial range are supplied in either ABS plastic, painted steel, stainless steel or phenolic and are offered in Type 1 or 2 (standard or case with blow-out disk).

 

Gauge Filling

Both pulsation and vibration will decrease gauge life if not properly dampened. Gauges subject to pulsation and vibration should be liquid filled or internally dampened. Available accessories that minimise stresses on the Bourdon tube/movement and extend the life of the gauge include pulsation dampeners, pressure snubbers, gauge savers, diaphragm seals and (pigtail) siphons. Gauges from Brannan’s standard industrial range requiring dampening are glycerine filled.

 

For more information about any of our gauges, please contact us at sales@brannan.co.uk 

brannan customer service person

Got a Question? Let us Help.

Our experienced, friendly team are happy to help. Get in touch today.

Download a Catalogue

Choose from our range of catalogues to see our full range of products.

Latest News

News   31_158   listing tile

High Precision "Paddle " Thermometer

main image scaled

Heavy duty environmental meters

main image scaled

Dial Compost Thermometer

View all news

Latest News

Banner   Fire Sprinkler Gauge   desktop

Fire sprinkler pressure gauge

Banner   Pressure test plug kit   desktop

Pressure and thermometer test plug kit

Banner   In house dial manufacture   desktop

In-house-instrumentation-production

View all news

This site uses cookies to monitor site performance and provide a mode responsive and personalised experience. You must agree to our use of certain cookies. For more information on how we use and manage cookies, please read our Privacy Policy.